COMWAY MAX-600-M2-P=M5 High-Dynamic-Range Dual SM OTDR (1310/1550)
📦Fast Shipping: All in-stock items are dispatched immediately. Remaining items will follow as soon as they arrive in our warehouse. (Usually 4 to 6 weeks).
☎️Contact us: for more information on our current stockholding or for a specific configuration.
💳Secure payments: Every payment you make is secured with strict SSL encryption and PCI DSS data protection protocols.
🚚Delivery via Trusted Courier: Expect your order to be delivered promply.
🔙Money-back protection: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
(Note: Typical delivery time is 2 to 4 weeks from order,
Standard OTDR Port is SC/APC, contact us for a different configuration)
The COMWAY MAX-600-M2-P=M5 is a professional-grade, DUAL-Wavelength (1310/1550), high dynamic range Optical Time-Domain Reflectometer (OTDR) engineered for telecom professionals and network engineers.
Housed in a lightweight, field-ruggedized chassis, the M2-P=M5 variant of the MAX-600 series steps up performance with an increased high dynamic range of 43dB /41dB. This allows field crews to accurately test, troubleshoot, and map metro links, access networks, and long-distance fiber spans up to 120km with absolute precision.
Featuring an outdoor-enhanced 7.0-inch touchscreen and an all-in-one testing suite (built-in OPM, OLS, VFL, and intelligent link mapping), the MAX-600-M2-P=M5 dramatically accelerates field commissioning and fiber fault isolation.
Key Features & Benefits:
-
High-Dynamic Mid-Range Reach: Delivers an impressive 43dB at 1310nm and 41dB at 1550nm, giving technicians the power to shoot through high-attenuation splitters and longer fiber infrastructure spans.
-
Ultra-Short Dead Zones: Engineered with an extra-short ≤ 0.8m Event Dead Zone and a 4m Attenuation Dead Zone, allowing for flawless detection of closely spaced connectors, mechanical splices, and patch panel faults.
-
Intelligent Map Link (iOLA/iOLM): Eliminates complex trace interpretation. With a single tap, the software converts raw OTDR data into a clean, icon-based linear schematic highlighting splitters, macrobends, bad splices, and connectors.
-
Massive Trace Memory Capacity: Features expansive internal storage capable of holding >80,000 professional OTDR traces in industry-standard
.SORor.PDFformats for quick cloud offloading and report generation. -
All-In-One Smart Architecture: Ships standard with an integrated Visual Fault Locator (10mW VFL), Optical Power Meter (OPM), Stable Light Source (OLS), and supporting RJ45 cable sequence/length testing.
-
Built for the Field: Weighing just 1.0kg with a 12-hour continuous battery life, it provides full-shift utility in severe environments spanning from -10° to +50°.
COMWAY MAX-600-M2: High-Loss Splitters & Regional Metro Links:
The M2 boosts the optical power output to a massive 43dB, specifically intended for infrastructure environments with heavy insertion losses.
-
Metropolitan Area Networks (MANs): Ideal for regional utility links, city-wide loops, and dark fiber auditing stretching across distances up to 150+ km.
-
Congested Distribution Cabinets: Uses a tight 4.0m attenuation dead zone to successfully distinguish between closely spaced patches and connectors inside high-density street cabinets.
📊What is iLOA?
iLOA (Intelligent Optical Link Analyzer) is an automated software tool that removes the complexity from fiber optic testing. Instead of requiring a technician to manually configure settings and interpret a complex, jagged trace graph, iLOA does all the heavy lifting automatically.
How It Works & Benefits:
-
Multi-Pulse Automation: It automatically shoots multiple different pulse widths down the fiber and fuses the data together, capturing both close-up connectors and long-distance faults with perfect clarity.
-
Icon-Based Mapping: It translates the confusing raw waveform data into a simple, linear map using clear icons for splices, splitters, connectors, and macro-bends.
-
Instant Pass/Fail Diagnosis: Elements are color-coded (Green for Pass, Red for Fail). Technicians can see exactly what the problem is and its precise distance in seconds.
The Bottom Line: iLOA eliminates human error and bridges the skills gap, allowing field technicians of any experience level to troubleshoot FTTH and metro networks rapidly and flawlessly.
Comparison: Why Upgrade to the M2 Module?
While the MAX-600-M1 configuration is tailored for local FTTH drops with its 32/30dB range, the MAX-600-M2-P=M5 features beefed-up internal optics pushing it to 43/41dB. This makes it the go-to choice if your technicians regularly work past local distribution cabinets and find themselves managing central-office-to-node metrics, testing loaded PON distribution networks, or handling metropolitan enterprise links.
Standard Package Contents:
-
COMWAY MAX-600-M2 Handheld OTDR Mainframe
-
FC & SC Interchangeable Fiber Optical Adapters
-
AC/DC Power Adapter/Charger (100-240V Input, 12V Output)
-
Quick-Start User Manual & Calibration Certificate
-
Heavy-Duty Rugged Carrying Case with Shoulder Strap
🔬 Key Technical Specifications:
- Wavelengths: 1310nm / 1550nm
- Dynamic Range: 43dB (1310nm) / 41dB (1550nm)
- Event Dead Zone: ≥0.8m
- Display: 7-inch Full Touchscreen
- Battery: 7.4V, 4,600mAh | 12-hour life
-
Weight: 1.55kg | Dimensions: 246×174×70mm
- Operating Temp: -10°C to +50°C
- Functions: OTDR + VFL + OPM
- Connector Options: SC/APC standard | FC/APC | SC/UPC | FC/UPC
☑️ Comparison Chart:
|
Module |
MAX-600-M1 |
MAX-600-M2 |
MAX-600-M3 |
MAX-600-M3A |
MAX-600-M4 |
|
Wavelength(nm) |
1310/1550 |
1310/1550 |
1310/1550 |
1310/1550 |
850/1300/ |
|
Wavelength Accuracy(nm) |
±20 |
||||
|
Dynamic range(dB) |
32/30 |
40/38 |
39/38/38 |
36/34/32 |
26/26/36/34 |
|
Event dead zone(m) |
1.5 |
0.8 |
0.8 |
0.8 |
SM≤0.8m |
|
Attenuation dead zone(m) |
6 |
4 |
4 |
4 |
SM≤3m |
|
Pulse width(ns) |
3ns/5ns/10ns/25ns/50ns/100ns/250ns/500ns/1μs/2.5μs/5μs/10μs/20μs |
||||
|
Distance range |
100m/500m/1km/2.5km/10km/20km/40km/60km/80km/100km/120km/ |
||||
|
Distance uncertainty(m) |
± (0.8+0.005% x distance + sampling resolution) |
||||
|
Linearity(dB/dB) |
±0.03 |
||||
|
Loss threshold (dB) |
0.01 |
||||
|
Loss resolution(dB) |
0.001 |
||||
|
Measurement time |
5s-5mins, real-time |
||||
|
Typical real-time refresh (Hz) |
4 |
||||
|
Power meter |
-50~+26dBm, 850/1300/1310/1490/1550/1625nm, FC or SC adapter |
||||
|
VFL |
650nm±10nm, 10mW |
||||
|
Display |
7-inch (178 mm) outdoor-enhanced touchscreen, 800x480TFT |
||||
|
Interfaces |
One USB 2.0 port; RJ-45×1, LAN,10/100 Mbit/s, Micro SDx1. |
||||
|
Storage |
>10000 results (SOR or PDF) |
||||
|
Battery Life |
7.4V, 4600mAh lithium battery pack |
||||
|
Power consumption |
<3W |
||||
|
Power supply |
Power supply AC/DC adapter, AC input 100-240V, 50-60Hz, DC out 12V, 1.5A |
||||
|
Applicable environment |
Operating temperature range: -10℃~+50℃, Relative humidity: -40℃~+70℃ |
||||
|
Dimensions (WxHxD) |
246.5*173.5*70mm |
||||
|
Weight (including battery) |
1.55kg |
||||